Key result
The optimized aortic microcalcification activity method demonstrated excellent agreement with the established tissue to background ratio method for quantifying 18F-sodium fluoride uptake (ICC 0.97) and was three-fold quicker to perform.
Why the study?
Aortic microcalcification activity is a newly described PET method in the thoracic aorta, but needed comparison and modification for the infrarenal aorta in abdominal aortic aneurysms.
Does the aortic microcalcification activity (AMA) method provide comparable and faster quantification of 18F-sodium fluoride uptake compared to the tissue to background ratio (TBR) method in patients with abdominal aortic aneurysms?
Observational (n=25)
Does the aortic microcalcification activity (AMA) method provide comparable and faster quantification of 18F-sodium fluoride uptake compared to the tissue to background ratio (TBR) method in patients with abdominal aortic aneurysms?
Effect estimate: ICC 0.97 (95% CI 0.94-0.99)
The aortic microcalcification activity method provides a rapid and highly repeatable alternative to conventional tissue-to-background ratio for quantifying 18F-sodium fluoride PET uptake in abdominal aortic aneurysms.
Background: Aortic microcalcification activity is a recently described method of measuring aortic 18F-sodium fluoride uptake in the thoracic aorta on positron emission tomography . In this study, we aimed to compare and to modify this method for use within the infrarenal aorta of patients with abdominal aortic aneurysms.Methods: Twenty-five patients with abdominal aortic aneurysms underwent an 18F-sodium fluoride positron emission tomography and computed tomography scan. Maximum and mean tissue to background ratios (TBR) and abdominal aortic microcalcification activity were determined following application of a thresholding and variable radius method to correct for vertebral 18F-sodium fluoride signal spill-over and the non-linear changes in aortic diameter respectively. Agreement between the methods, and repeatability of these approaches were assessed.Results: The aortic microcalcification activity method was three-fold quicker to perform than the TBR method (14 versus 40 min, p<0.001). There was moderate to good agreement between TBR and aortic microcalcification activity measurements for maximum (interclass correlation co-efficient, 0.67) and mean (interclass correlation co-efficient, 0.88) values. These correlations sequentially improved with the application of thresholding (intraclass correlation coefficient 0.93, 95% confidence interval 0.89-0.95) and variable diameter (intraclass correlation coefficient 0.97, 95% confidence interval 0.94-0.99) techniques. The optimized method had good intra-observer (mean 1.57 ± 0.42, bias 0.08, co-efficient of repeatability 0.36 and limits of agreement -0.43 to 0.43) and inter-observer (mean 1.57 ± 0.42, bias 0.08, co-efficient of repeatability 0.47 and limits of agreement -0.53 to 0.53) repeatability.Conclusions: Aortic microcalcification activity is a quick and simple method which demonstrates good intra-observer and inter-observer repeatabilities and provides measures of 18F-sodium fluoride uptake that are comparable to established methods.
No takes yet. Share an insight, caveat, or question.
Debono et al. (2022) conducted an observational in Abdominal aortic aneurysms (n=25). Aortic microcalcification activity (AMA) method vs. Tissue to background ratio (TBR) method was evaluated on Agreement between mean aortic microcalcification activity (with variable radius) and mean tissue to background ratio (ICC 0.97, 95% CI 0.94-0.99). The optimized aortic microcalcification activity method demonstrated excellent agreement with the established tissue to background ratio method for quantifying 18F-sodium fluoride uptake (ICC 0.97) and was three-fold quicker to perform.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: