Answers are grounded in this paper and cite their sources.
Utilization of 10ºC static storage safely extended both ischemic time and travel radius in heart transplantation. A 57-year-old man with ischemic cardiomyopathy, a left ventricular assist device (LVAD), and end-stage renal disease was listed for combined heart-kidney transplant. The donor hospital in Anchorage, AK, was located approximately 2,700 nautical miles and 8 hours from the recipient center. The organ was transported in 10ºC static storage with over 10 hours of ischemic time and had superb early allograft function. Excellent outcomes with extended ischemic times can be achieved without machine perfusion, provided good recovery, storage, and implant techniques are followed.
No takes yet. Share an insight, caveat, or question.
Tucker et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: