Answers are grounded in this paper and cite their sources.
In this paper, a robust control method based on a disturbance observer is proposed to regulate the terminal voltage of a photovoltaic generator, interfaced by a current mode-controlled boost dc-dc converter. The combined generator-converter-load system possesses a nonlinear behavior, highly dependent on operation point and environmental variables, thus burdening the control task. It is shown that employing a typical linear controller, designed according to a single nominal operating point, results in a closed-loop performance, varying from a highly overdamped near open-circuit condition to greatly underdamped around short-circuit conditions. On the other hand, when the proposed robust controller is utilized, the closed-loop performance remains nearly nominal throughout the whole operation range. In addition, it is shown that, by sacrificing the performance in the vicinity of the open-circuit point, it is possible to implement the controller using a single op-amp with a reduced part count. Simulation and experimental results are presented to verify the proposed method.
No takes yet. Share an insight, caveat, or question.
Sitbon et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: