Key result
Surgical management combined with transvenous extraction tools achieved successful lead removal and survival to discharge in 100% of high-risk patients unsuitable for isolated transvenous extraction.
Why the study?
Surgical approaches are more invasive than transvenous extraction for infected or failing CIED leads, but remain necessary for patients deemed unsuitable for transvenous procedures.
Observational (n=9)
No
Combining surgical procedures with transvenous extraction tools is a safe and effective strategy for removing CIED leads in high-risk patients unsuitable for transvenous extraction alone.
Hybrid extraction feasible in select high-risk CIED cases; leaves open need for larger prospective studies before wider adoption.
BACKGROUND: Although surgical approaches for infected or failing cardiac implantable electronic device (CIED) leads are more invasive than transvenous approaches, they are still required for patients considered unsuitable for transvenous procedures. In this study, surgical management with transvenous equipment for CIED complications was examined in patients unsuitable for transvenous lead extraction. METHODS AND RESULTS: We retrospectively examined 152 consecutive patients who underwent CIED extraction between April 2009 and December 2021 at the Department of Cardiovascular Surgery, Nippon Medical School. Nine patients (5.9%; mean [±SD] age 61.7±16.7 years) who underwent open heart surgery were identified as unsuitable for the isolated transvenous approach. CIED types included 5 pacemakers and 4 implantable cardioverter-defibrillators; the mean [±SD] lead age was 19.5±7.0 years. Indications for surgical management according to Heart Rhythm Society guidelines included failed prior to transvenous CIED extraction (n=6), intracardiac vegetation (n=2), and severe lead adhesion (n=1). Transvenous CIED extraction tools were used in all patients during or before surgery. Additional surgical procedures with CIED extraction included epicardial lead implantation (n=4) and tricuspid valve repair (n=3). All patients were discharged; during the follow-up period (mean 5.7±3.7 years), only 1 patient died (non-cardiac cause). CONCLUSIONS: Surgical procedures and transvenous extraction tools were combined in the removal strategy for efficacious surgical management of CIED leads. Intensive surgical procedures were safely performed in patients unsuitable for transvenous extraction.
No takes yet. Share an insight, caveat, or question.
Miyagi et al. (2022) conducted an observational in Cardiac implantable electronic device (CIED) complications unsuitable for transvenous lead extraction (n=9). Surgical management combined with transvenous extraction tools was evaluated on Successful lead extraction and survival to discharge. Surgical management combined with transvenous extraction tools achieved successful lead removal and survival to discharge in 100% of high-risk patients unsuitable for isolated transvenous extraction.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: