This is the authors' abstract. We don't add key points for this paper.
PURPOSE: To assess the long-term safety and efficacy of the 0.19-mg fluocinolone acetonide (FAc) intravitreal implant (Iluvien; Alimera Sciences, Inc) in patients with diabetic macular edema (DME). DESIGN: Three-year, phase 4, nonrandomized, open-label observational study. PARTICIPANTS: Patients with DME who previously received corticosteroid treatment without a clinically significant rise in intraocular pressure (IOP; all eyes, n = 202 eyes of 159 patients; 36-month completion, n = 94 eyes). METHODS: A prospective, observational study in which patients received a 0.19-mg FAc intravitreal implant at baseline and then were observed for safety-, visual-, anatomic-, and treatment burden-related outcomes for up to 36 months. MAIN OUTCOME MEASURES: Primary safety outcomes included changes in IOP and interventions to manage IOP elevations. Secondary outcomes included changes in best-corrected visual acuity (BCVA), central subfield thickness (CST), and adjunctive DME treatment frequency RESULTS: At 36 months after FAc implantation, study eyes showed a mean CST change of -60.69 μm (P < 0.0001) and a mean BCVA change of +3.61 letters (P = 0.0222) compared with baseline. Overall median treatment frequency decreased from 3.4 treatments/year in the 36 months before FAc implantation to 1 treatment/year in the 36 months after FAc implant, a treatment burden reduction of 70.5%. Furthermore, among the group that completed 36 months of treatment (n = 94 eyes), 25.53% of eyes remained rescue free through 36 months. Mean IOP remained stable throughout the study, and IOP increases to more than 30 mmHg occurred in 10.89% of eyes. Intraocular pressure-related procedures were infrequent, with a surgical rate of 2.97%, with 1.49% attributable to steroid use (vs. surgeries attributable primarily to neovascular glaucoma). In addition, an IOP response of < 25 mmHg after the steroid challenge predicted that 96.92% of eyes would have a similar outcome to 0.19-mg FAc implant at the last visit. Intraocular pressure increases that did occur were manageable with standard treatments (n = 202 eyes). CONCLUSIONS: In patients with DME, the 0.19-mg FAc implant provided improved visual outcomes and reduced treatment burden compared with previous treatments while maintaining a favorable safety profile.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Singer et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: