Key result
Dual-source computed tomography measurements of global left ventricular function showed excellent correlation with cardiovascular magnetic resonance (r=0.91-0.97, P<0.001) in valvular heart disease.
Why the study?
Does dual-source computed tomography accurately assess global left ventricular function compared to cardiovascular magnetic resonance and 2D-TTE in patients with valvular heart disease?
Cross-Sectional (n=111)
Independent readers
Does dual-source computed tomography accurately assess global left ventricular function compared to cardiovascular magnetic resonance and 2D-TTE in patients with valvular heart disease?
Effect estimate: r = 0.91-0.97
p-value: p=<0.001
Dual-source computed tomography provides highly reproducible and accurate quantification of global left ventricular function in patients with valvular heart disease, comparing favorably with cardiovascular magnetic resonance.
DSCT may support LV function assessment in valvular disease when CMR is limited; leaves open prospective outcome validation.
BACKGROUND: Left ventricular (LV) function is a vital parameter for prognosis, therapy guidance, and follow-up of cardiovascular disease. Dual-source computed tomography (DSCT) provides an accurate analysis of global LV function. PURPOSE: To assess the performance of DSCT in the determination of global LV functional parameters in comparison with cardiovascular magnetic resonance (CMR) and two-dimensional transthoracic echocardiography (2D-TTE) in patients with valvular heart disease (VHD). MATERIAL AND METHODS: A total of 111 patients (58 men, mean age 49.9 years) with known VHD and who underwent DSCT, 2D-TTE, and CMR a period of 2 weeks before undergoing valve surgery were included in this study. LV end-systolic volume (ESV), end-diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF) were calculated by DSCT using the threshold-based technique, by 2D-TTE using a modified Simpson's method, and by CMR using Simpson's method. Agreement for parameters of LV global function was determined with the Pearson's correlation coefficient (r) and Bland-Altman analysis. All the DSCT and CMR data-sets were assessed independently by two readers. RESULTS: Fifty of the total 111 patients had aortic VHD, 29 patients had mitral VHD, and 32 patients had mixed aortic and mitral VHD. An excellent inter-observer agreement was seen for the assessment of global LV function using DSCT (r = 0.910-0.983) and CMR (r = 0.854-0.965). An excellent or good correlation (r = 0.93, 0.95, 0.87, and 0.71, respectively, P < 0.001) was noted between the DSCT and 2D-TTE values for EDV, ESV, SV, and EF. EDV (33.7 mL, P < 0.001), ESV (12.1 mL, P < 0.001), SV (21.2 mL, P < 0.001), and EF (1.6%, P = 0.019) were significantly overestimated by DSCT when compared with 2D-TTE. An excellent correlation (r = 0.96, 0.97, 0.91, and 0.94, respectively, P < 0.001) between DSCT and CMR was seen in the evaluation of EDV, ESV, SV, and EF. EDV (15.9 mL, P < 0.001), ESV (7.3 mL, P < 0.001), and SV (8.5 mL, P < 0.001) were significantly underestimated, but EF (1.1%, P = 0.002) was significantly overestimated by DSCT when compared with CMR. CONCLUSION: Our study showed that DSCT measurements of global LV function using the threshold-based technique were highly reproducible and compared more favorably with CMR measurements using Simpson's method than those of 2D-TTE using the modified Simpson's method. DSCT enables accurate quantification of global LV function in patients with VHD.
No takes yet. Share an insight, caveat, or question.
Bak et al. (2012) conducted a cross-sectional in Valvular heart disease (n=111). Dual-source computed tomography (DSCT) vs. Cardiovascular magnetic resonance (CMR) and two-dimensional transthoracic echocardiography (2D-TTE) was evaluated on Correlation of left ventricular functional parameters (EDV, ESV, SV, EF) between DSCT and CMR (r = 0.91-0.97, p=<0.001). Dual-source computed tomography measurements of global left ventricular function showed excellent correlation with cardiovascular magnetic resonance (r=0.91-0.97, P<0.001) in valvular heart disease.