Key result
A sandwich technique using a Teflon felt plug successfully achieved hemostasis and closure of a type III left ventricular rupture after mitral valve replacement, with normal valve function at 2 years.
Why the study?
Does a sandwich technique using a Teflon felt plug improve hemostasis and prevent collateral tears in patients with left ventricular rupture after mitral valve replacement?
Case Report (n=1)
Does a sandwich technique using a Teflon felt plug improve hemostasis and prevent collateral tears in patients with left ventricular rupture after mitral valve replacement?
The sandwich technique using a Teflon felt plug is a viable surgical option to repair type III left ventricular ruptures after mitral valve replacement by reducing suture tension and preventing collateral tears.
May support sandwich Teflon plug repair in select type III LV rupture post-MVR; hypothesis-generating from single case.
One difficulty with external repair of left ventricular rupture after mitral valve replacement is collateral bleeding in friable myocardium adjacent to the rupture. The bleeding is caused by tension on the closing sutures, whether or not pledgets have been used. We report the case of a 69-year-old woman who underwent an uneventful mitral valve replacement. After cardiopulmonary bypass was terminated, brisk bleeding started from high in the posterior left ventricular wall, typical of a type III defect. We undertook external repair, placing a plug of Teflon felt into the cavity of the rupture and sandwiching it into place with pledgeted mattress and figure-of-8 sutures. The space occupied by the plug decreased the distance needed to obliterate the defect and thereby reduced the tension on the sutures necessary to achieve hemostasis. This simple technique enabled closure of the defect and avoided collateral tears that would have compromised an otherwise successful repair. Two years postoperatively, the patient had normal mitral valve function and no left ventricular aneurysm. In addition to reporting the patient's case, we review the types of left ventricular rupture that can occur during mitral valve replacement and discuss the various repair options.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2014) conducted a case report in Left ventricular rupture after mitral valve replacement (n=1). Sandwich technique using a plug of Teflon felt and pledgeted sutures was evaluated on Hemostasis and closure of the defect without collateral tears. A sandwich technique using a Teflon felt plug successfully achieved hemostasis and closure of a type III left ventricular rupture after mitral valve replacement, with normal valve function at 2 years.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: