Key result
Percutaneous paravalvular leak closure after TAVR achieved successful transcatheter occluder plug delivery in 78% of patients, reducing PVL to less than moderate in 72%.
Why the study?
Does percutaneous PVL closure improve PVL severity in patients with clinically significant PVL after TAVR?
Observational (n=18)
No
Does percutaneous PVL closure improve PVL severity in patients with clinically significant PVL after TAVR?
Percutaneous PVL repair following TAVR is feasible and effective, achieving procedural success in 78% of cases and reducing PVL to mild or less in the majority of patients.
Supports feasibility of post-TAVR PVL closure in selected patients; leaves open randomized confirmation of clinical benefit.
OBJECTIVES: To investigate the feasibility, procedural success, and outcomes of paravalvular leak (PVL) closure in patients with prior transcatheter aortic valve replacement (TAVR). BACKGROUND: PVL after TAVR is associated with adverse patient outcomes and increased mortality. Percutaneous PVL closure has emerged as a therapeutic strategy for addressing this issue, but data for transcatheter PVL repair after TAVR remains limited. METHODS: This is a single center retrospective review of PVL closure after TAVR. Patients with balloon-expandable or self-expanding prostheses were included. Baseline patient demographics, procedural characteristics, complications, and clinical outcomes were reviewed. RESULTS: A total of 18 patients with clinically significant PVL after TAVR referred for PVL closure were identified during the study period. Procedural success resulting in successful transcatheter occluder plug delivery was 78% (14 cases). Balloon postdilatation (2/4) and valve-in-valve (2/4) were used effectively in the remaining patients after an unsuccessful PVL closure attempt. PVL grading by echocardiography decreased from moderate or severe to < moderate in 13 patients (72%). Adverse events including cardiac tamponade and acute kidney injury occurred in 1 case each. One-month all-cause mortality was 11%. CONCLUSION: In selected patients, percutaneous PVL repair following TAVR is feasible and effective for both balloon-expandable and self-expanding prostheses. Most patients undergoing PVL closure after TAVR require a single occluder plug placement for reduction in PVL to mild or less.
No takes yet. Share an insight, caveat, or question.
Waterbury et al. (2017) conducted an observational in Paravalvular leak after transcatheter aortic valve replacement (n=18). Percutaneous paravalvular leak closure was evaluated on Procedural success (successful transcatheter occluder plug delivery). Percutaneous paravalvular leak closure after TAVR achieved successful transcatheter occluder plug delivery in 78% of patients, reducing PVL to less than moderate in 72%.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: