Samples of Si 3 N 4 made by chemical vapor deposition (CVD) and hot isostatic pressing (HIP) were exposed for 10 h at 1400°C to H 2 –H 2 O and Ar–O 2 environments. Variations in weight and surface morphology of the CVD‐Si 3 N 4 samples were monitored to determine the corrosion behavior of ‘pure’ Si 3 N 4 as baseline information. Additionally, the room‐temperature flexural strengths of the HIP‐Si 3 N 4 were determined and correlated with observed changes in weight and microstructure. The corrosion behavior of both materials depended on the level of oxidant (H 2 O or O 2 ) in the atmosphere, but the magnitudes of the weight changes observed in the HIP‐Si 3 N 4 were significantly greater. When the P H2O in the H 2 atmospheres was low ( P H2O < × 10 −5 MPa), significant weight loss and surface degradation occurred in both ceramics, accompanied by reductions in strength of the HIP‐Si 3 N 4 . However, in atmospheres with P H2O 1 × 10 −4 MPa, the weight loss was smaller and the strength of the HIP‐Si 3 N 4 was greater than that of the as‐received material. Somewhat different behavior was observed in samples exposed to Ar–O 2 environments. Weight loss of both silicon nitrides increased with increasing P o2 until a level of about 2 × 10 −5 MPa was reached. However, contrary to the results for H 2 –H 2 O exposures, even under these conditions the strength of the HIP‐Si 3 N 4 material was found to have increased above that of the as‐received material.
No takes yet. Share an insight, caveat, or question.
Kim et al. (1990) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: