Key result
Total hip and total knee replacement procedures lead to an almost doubled D-dimer level during the 10-day post-operative period, following a sinusoid pattern that does not indicate a higher risk of thromboembolic disease.
Why the study?
How do D-dimer levels fluctuate in the post-operative period in patients undergoing cemented or cementless total hip or total knee replacement?
Observational (n=47)
No
How do D-dimer levels fluctuate in the post-operative period in patients undergoing cemented or cementless total hip or total knee replacement?
D-dimer levels naturally double and fluctuate in a sinusoidal pattern up to 10 days following major orthopedic surgery, indicating that elevated D-dimers alone should not be used to diagnose post-operative venous thromboembolism.
Answers are grounded in this paper and cite their sources.
Elevated D-dimer post-arthroplasty should not alone prompt VTE evaluation; observational data supports cautious interpretation but leaves prospective validation open.
INTRODUCTION: The number of total hip and total knee replacement procedures performed worldwide has tended to surge in recent years, due to the combination of such factors as the increased life expectancy, improved quality of life, advances in medical technology as well as pre-operative and post-operative patient management.Numerous studies confirm that patients undergoing major orthopaedics procedures involving lower extremities, for instance total hip and total knee replacement, constitute the highest risk group for the development of post-operative venous thromboembolism (VTE), primarily manifested as deep vein thrombosis (DVT). PURPOSE: The purpose of the research was to assess the dynamics of D-dimer level fluctuation during the post-operative period in patients after the cemented or cementless total hip replacement (THR) or total knee replacement (TKR), in order to prove or reject the thesis that the cemented and cementless THR or TKR affects the post-operative D-dimer levels. MATERIAL AND METHODS: The study group consisted of 47 patients aged 29-82 years. Of them, 23 had the cementless THR, 12 subjects had the cemented THR and another 12 patients had the TKR. All of the patients performed to measure the concentration of D-dimers in the peri-operative period at predetermined time points. For the peri-operative period was adopted from time 1 day before surgery to 10-day hospitalization. The subarachnoid block (SAB) was performed in all patients. RESULTS: The distribution of D-dimer values throughout the entire post-operative period (up to 10th post-operative day) followed the sinusoid pattern with two peaks in all patients. It was not specific in any group. CONCLUSIONS: 1. The D-dimer level almost doubles during the post-operative period in patients after THR or TKR.2. Higher level of D-dimers in post-operative period in the research group of patients does not relate to higher risk of thromboembolic disease.
No takes yet. Share an insight, caveat, or question.
Bytniewski et al. (2014) conducted an observational in Degenerative hip or knee lesions requiring joint replacement (n=47). Total hip or total knee replacement vs. Pre-operative baseline was evaluated on D-dimer level fluctuation during the 10-day post-operative period (p=<0.001). Total hip and total knee replacement procedures lead to an almost doubled D-dimer level during the 10-day post-operative period, following a sinusoid pattern that does not indicate a higher risk of thromboembolic disease.
Synapse has enriched 10 related papers. Consider them for comparative context: