Many surgical techniques to repair late in-the-bag intraocular lens (IOL) dislocation have been described. We present a modification to ab externo scleral fixation of in-the-bag IOL dislocation that minimizes cumbersome intraocular manipulations. Using an iris hook for intraocular suture retrieval under direct visualization eliminates the need to mate the suture needle with a hypodermic needle, and the site through which the hook is used provides an ideal place for suture knot burial, potentially minimizing late suture erosion or exposure. Financial Disclosure: Neither author has a financial or proprietary interest in any material or method mentioned.
No takes yet. Share an insight, caveat, or question.
Kirk et al. (2012) studied this question.