Several techniques are used to reposition dislocated intraocular lenses (IOLs). Most place a suture loop around the end of the haptic. However, in cases of a dislocated capsular bag containing the IOL, a dislocated IOL with a large haptic, or a miotic pupil, it is not easy to see the haptic ends to place the suture loop. We describe a scleral fixation technique that uses 2 corneal tunnels. A double-armed 10-0 polypropylene suture loop can be introduced through 1 corneal tunnel and placed around any accessible part of the haptic with the help of a bent 26 gauge needle. This modified technique is an easy and effective way to reposition the IOL.
No takes yet. Share an insight, caveat, or question.
Koh et al. (2000) studied this question.