Key result
Left atrium dimension > 4 cm was an independent predictor of death in hemodialysis patients (HR 3.76; 95% CI 1.56-9.03; p < 0.01).
Observational (n=106)
No
Hazard Ratio: 3.76 (95% CI 1.56–9.03)
p-value: p=< 0.01
May aid prognostication in hemodialysis; hypothesis-generating and requires prospective validation.
BACKGROUND: In order to evaluate the predictive value of echocardiograph parameters for mortality of hemodialysis patients and their relation to Kt/V and anthropometry, a prospective, single center study was analyzed post-hoc. METHODS: This analysis encompassed 106 patients on maintenance hemodialysis monitored for 108 months from 1996 to 2004. spKt/V was calculated using the Daugirdas formula. Anthropometric measurements included mid-arm muscle measurements (MAMC) and percentage of body fat (%fat). Echocardiography included the estimations of left ventricular wall thickness, dimensions and volumes (EDV, ESV), systolic LV function (ejection fraction - EFLV, fractional shortening - VCF, stroke volume - SV) and diastolic LV function (E/A, VTI-A wave of transmitral flow velocity), left atrial diameter, as well as assessment of clinical and biochemical parameters. The Cox proportional hazard model was used to estimate predictive values of echocardiograph parameters. RESULTS: Kt/V correlated significantly with left ventricular systolic and diastolic volumes and function, septal and posterior wall thickness and left atrium dimension. MAMC and %fat also correlated with many echocardiograph parameters. Multivariate Cox regression selected age [HR 1.07; CI (1.03-1.12); p < 0.01], albumin [HR 0.88; CI (0.79-0.97); p < 0.05] and left atrium dimension - binary [values > 4 cm were marked as "1" and others "0" - HR 3.76; CI (1.56-9.03); p < 0.01] as independent predictors of death. CONCLUSION: Left atrium dimension was the most important predictor of mortality among the echocardiograph parameters. Many of these parameters were related to Kt/V and anthropometric measurements and could be the combined consequence of hypervolemia and hypertension.
No takes yet. Share an insight, caveat, or question.
Stošović et al. (2015) conducted an observational in maintenance hemodialysis (n=106). Left atrium dimension > 4 cm vs. Left atrium dimension ≤ 4 cm was evaluated on mortality (HR 3.76, 95% CI 1.56-9.03, p=< 0.01). Left atrium dimension > 4 cm was an independent predictor of death in hemodialysis patients (HR 3.76; 95% CI 1.56-9.03; p < 0.01).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: