This is the authors' abstract. We don't add key points for this paper.
Denaturing gradient gel electrophoresis (DGGE), a mutation-scanning procedure separating DNA fragments differing by as little as a single base change, is widely used in studies of genomic nucleotide sequence variability. The efficiency of the technique is greatly enhanced by attaching, through polymerase chain reaction (PCR) incorporation, a long GC-tail to the test DNA sequence which, as a result, becomes analysable throughout. As synthesis of GC-rich specific PCR primers is costly and time-consuming, we attempted to clamp the DNA fragment using a psoralen derivative (ChemiClamp) that promotes photo-induced cross-linking at one end. We found that this procedure provides an attractive alternative to GC-clamp in DGGE (and temperature gradient gel electrophoresis) and should prove useful in both research and diagnostic laboratories.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Costes et al. (1993) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: