Key result
Biodegradable-polymer biolimus-eluting stents showed similar 12-month rates of major adverse cardiac events compared to durable-polymer everolimus-eluting stents (HR 0.768; 95% CI 0.421-1.44; P=0.388).
Why the study?
Does a biodegradable-polymer biolimus-eluting stent reduce major adverse cardiac events compared to a durable-polymer everolimus-eluting stent in patients with coronary artery disease undergoing percutaneous coronary intervention?
Cohort (n=3,270)
No
Does a biodegradable-polymer biolimus-eluting stent reduce major adverse cardiac events compared to a durable-polymer everolimus-eluting stent in patients with coronary artery disease undergoing percutaneous coronary intervention?
Hazard Ratio: 0.768 (95% CI 0.421–1.44)
Absolute Event Rate: 2.7% vs 2.7%
p-value: p=0.388
Biodegradable-polymer biolimus-eluting stents demonstrate comparable safety and efficacy to durable-polymer everolimus-eluting stents at 1-year follow-up in patients undergoing percutaneous coronary intervention.
Similar MACE rates in this cohort support short-term comparability; leaves open confirmation in randomized trials.
We compared outcomes of percutaneous coronary intervention patients who received biodegradable-polymer biolimus-eluting stents with those who received durable-polymer everolimus-eluting stents. At Tehran Heart Center, we performed a retrospective analysis of the data from January 2007 through December 2011 on 3,270 consecutive patients with coronary artery disease who underwent percutaneous coronary intervention with the biodegradable-polymer biolimus-eluting stent or the durable-polymer everolimus-eluting stent. We excluded patients with histories of coronary artery bypass grafting or percutaneous coronary intervention, acute ST-segment-elevation myocardial infarction, or the implantation of 2 different stent types. Patients were monitored for 12 months. The primary endpoint was a major adverse cardiac event, defined as a composite of death, nonfatal myocardial infarction, and target-vessel and target-lesion revascularization. Durable-polymer everolimus-eluting stents were implanted in 2,648 (81%) and biodegradable-polymer biolimus-eluting stents in 622 (19%) of the study population. There was no significant difference between the 2 groups (2.7% vs 2.7%; P=0.984) in the incidence of major adverse cardiac events. The cumulative adjusted probability of major adverse cardiac events in the biodegradable-polymer biolimus-eluting stent group did not differ from that of such events in the durable-polymer everolimus-eluting stent group (hazard ratio=0.768; 95% confidence interval, 0.421-1.44; P=0.388). We conclude that in our patients the biodegradable-polymer biolimus-eluting stent was as effective and safe, during the 12-month follow-up period, as was the durable-polymer everolimus-eluting stent.
No takes yet. Share an insight, caveat, or question.
Parsa et al. (2016) conducted a cohort in coronary artery disease (n=3,270). Biodegradable-polymer biolimus-eluting stents vs. Durable-polymer everolimus-eluting stents was evaluated on major adverse cardiac event, defined as a composite of death, nonfatal myocardial infarction, and target-vessel and target-lesion revascularization (HR 0.768, 95% CI 0.421-1.44, p=0.388). Biodegradable-polymer biolimus-eluting stents showed similar 12-month rates of major adverse cardiac events compared to durable-polymer everolimus-eluting stents (HR 0.768; 95% CI 0.421-1.44; P=0.388).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: