Key result
Atrial lead repositioning after left subclavian biventricular defibrillator implantation resulted in a contralateral pneumothorax that resolved with conservative management.
Contralateral pneumothorax is a potential complication of atrial lead repositioning, likely due to lead perforation, and can be managed conservatively.
Answers are grounded in this paper and cite their sources.
Clinicians should consider contralateral pneumothorax after atrial lead repositioning; case reports leave open systematic risk assessment.
A right-sided pneumothorax developed several hours after atrial lead repositioning following otherwise straightforward implantation of a biventricular defibrillator from a left subclavian approach. Right atrial lead perforation was presumed, though this could not be demonstrated on computed tomography. The patient was managed conservatively and made a full recovery.
No takes yet. Share an insight, caveat, or question.
Pettemerides et al. (2011) studied this question. Atrial lead repositioning after left subclavian biventricular defibrillator implantation resulted in a contralateral pneumothorax that resolved with conservative management.
Synapse has enriched 10 related papers. Consider them for comparative context: