Percutaneous placement of an implantable cardioverter defibrillator resulted in right atrial perforation and hemopneumothorax, which was successfully managed with thoracoscopic drainage and fibrin glue.
Case Report (n=1)
Active fixation leads during ICD placement can cause right atrial perforation leading to hemopneumothorax, requiring surgical intervention.
Answers are grounded in this paper and cite their sources.
Active fixation ICD leads may cause right atrial perforation with hemopneumothorax; this case leaves open questions on incidence and prevention.
Implantable cardioverter defibrillator (ICD) placements can be associated with serious complications. This paper reports a patient in whom percutaneous placement of an ICD resulted in a hemopneumothorax. This was due to an active fixation lead that perforated the right atrial wall and injured the adjacent lung parenchyma. The hemothorax was drained thoracoscopically, and the atrial injury was covered with fibrin glue.
No takes yet. Share an insight, caveat, or question.
Tran et al. (2001) conducted a case report in Right atrial perforation and hemopneumothorax (n=1). Implantable cardioverter defibrillator (ICD) insertion was evaluated on Hemopneumothorax due to right atrial wall perforation. Percutaneous placement of an implantable cardioverter defibrillator resulted in right atrial perforation and hemopneumothorax, which was successfully managed with thoracoscopic drainage and fibrin glue.