Key result
Functional electrical stimulated exercise caused significantly greater muscle glycogen depletion in the vastus lateralis (260 vs 45 mmol/kg) compared to voluntary exercise (p<0.05).
Why the study?
Does functional electrical stimulation compared to voluntary exercise alter muscle glycogen depletion and metabolic responses in healthy men?
Does functional electrical stimulation compared to voluntary exercise alter muscle glycogen depletion and metabolic responses in healthy men?
Absolute Event Rate: 260% vs 45%
p-value: p=< 0.05
Functional electrical stimulation during dynamic exercise causes significantly greater muscle glycogen depletion and higher metabolic responses compared to voluntary exercise at the same workload.
Should not yet change FES prescriptions in rehabilitation; hypothesis-generating for metabolic demands in clinical populations.
Muscle glycogen depletion pattern and metabolic responses during voluntary (VOL) and functional electrical stimulated (FES) dynamic knee-extensor exercise with one leg were evaluated. Seven healthy men exercised for 60 minutes at 30 W with an pulmonary oxygen uptake of 0.8 and 1.01 min-1, and respiratory exchange ratios of 0.90 and 0.95 in VOL and FES, respectively. Heart rate reached a level around 90 beats min-1 (VOL) and up to 110 beats min-1 (FES). Muscle glycogen decreased in FES with 260 and 290 mmol kg-1 d.w. in vastus lateralis and m. rectus femoris, respectively, compared with 45 and 160 mmol kg-1 d.w. in VOL (p < 0.05). In FES the percentage of empty and almost empty fibres determined by periodic acid-Schiff staining in vastus lateralis and rectus femoris was 50 and 77% of type I, 63 and 90% of type IIa, and 59 and 84% of type IIb fibres, respectively, whereas in VOL it was 24 and 26% of type I, 7 and 19% of type IIa, and 2 and 3% of type IIb fibres. Muscle lactate reached 30 mmol kg-1 d.w. in FES and was 9 mmol kg-1 d.w. lower in VOL. The changes in blood lactate and NH3 during the exercise were slightly higher in FES than in VOL, whereas the alterations in glucose, FFA, and K+ were small in both exercise modes. The pressure in the two muscle portions at different locations (proximal-distal) and depths was always higher (approximately 50%) in FES than in VOL, reaching levels around 55 mmHg.(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Kim et al. (2013) studied Healthy (n=7). Functional electrical stimulated (FES) dynamic knee-extensor exercise vs. Voluntary (VOL) dynamic knee-extensor exercise was evaluated on Muscle glycogen decrease in vastus lateralis (mmol kg-1 d.w.) (p=< 0.05). Functional electrical stimulated exercise caused significantly greater muscle glycogen depletion in the vastus lateralis (260 vs 45 mmol/kg) compared to voluntary exercise (p<0.05).