Key result
In a case series of 12 patients undergoing open thoraco-abdominal aortic repair, the single patient who experienced a significant intraoperative drop in paraspinous muscle oxygenation (<40%) measured by NIRS developed postoperative paraplegia.
Why the study?
The reliability of near-infrared spectroscopy of paraspinous muscles to monitor spinal cord oxygenation and predict spinal cord injury during open thoraco-abdominal aortic surgery required assessment.
Does near-infrared spectroscopy (NIRS) monitoring of paraspinous muscles predict spinal cord injury in patients undergoing open thoraco-abdominal aortic surgery?
Observational (n=12)
No
Does near-infrared spectroscopy (NIRS) monitoring of paraspinous muscles predict spinal cord injury in patients undergoing open thoraco-abdominal aortic surgery?
NIRS monitoring of paraspinous muscles may be a reliable tool to detect unsafe oxygenation levels and predict spinal cord injury during open thoraco-abdominal aortic surgery.
Objectives. We adopted the near-infrared spectroscopy (NIRS) technology to monitor the spinal oxygen supply through the paraspinous muscles oxygenation in agreement with the concept of “collateral network” circulation. We retrospectively investigated our database of subjects who underwent thoraco-abdominal aorta open repair assessing for the reliability of this monitoring to predict spinal cord injury. Methods. Consecutive patients who underwent elective thoraco-abdominal aorta open repair between March 2019 and September 2021. In addition to standard monitoring, patients received the monitoring of the paraspinous muscles oxygenation by NIRS. Results. In one patient a significant drop of the mean arterial pressure (49 mmHg) and the spinal-cord perfusion pressure (31 mmHg) occurred after the aortic clamping, with a contemporary lowering of the left-side oxygenation of paraspinous muscles (<40%). Both the blood pressure and the spinal cord perfusion pressure were restored within 10 minutes, but the oxygenation remained at an unsafe level (<55%) until the end of the surgery. This same patient experienced a lower-limb paralysis post-operatively. It did not happen in the other 11 cases of the sample. Conclusions. The main finding of our retrospective analysis indicates reliability of this technology to monitor the spinal cord oxygenation during open thoraco-abdominal aortic surgery and possibly predict spinal cord injury. Still, several questions need to be addressed about the suitability of this technology to the anatomic and pathophysiology of the spinal cord circulation
No takes yet. Share an insight, caveat, or question.
Giustiniano et al. (2022) conducted an observational in Thoraco-abdominal aortic aneurysm (n=12). Near-infrared spectroscopy (NIRS) monitoring was evaluated on Spinal cord injury (paraplegia). In a case series of 12 patients undergoing open thoraco-abdominal aortic repair, the single patient who experienced a significant intraoperative drop in paraspinous muscle oxygenation (<40%) measured by NIRS developed postoperative paraplegia.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: