Key result
Echo-pulsed Doppler successfully localized the origin of systolic clicks to the prolapsed anterior tricuspid leaflet in one patient and the aortic leaflet in another.
Why the study?
Does the Echo-pulsed doppler (EPD) technique localize the origin of systolic clicks in patients with systolic clicks?
Case Report (n=2)
Does the Echo-pulsed doppler (EPD) technique localize the origin of systolic clicks in patients with systolic clicks?
Echo-pulsed doppler appears to be a safe, noninvasive method for localizing the origin of systolic clicks.
Answers are grounded in this paper and cite their sources.
Suggests EPD feasibility for localizing systolic clicks; hypothesis-generating and should not yet change practice.
Echo-pulsed doppler (EPD) studies were performed in 2 surgically controlled patients with systolic clicks. The recorded blood samples documented the click to be originated in the right atrium, at the site of the prolapsed anterior tricuspid leaflet in 1 case of heroin-induced tricuspid acute endocarditis. In the second patient suffering from aortic valve disease, an ejection click was recorded, and could be demonstrated by using EPD, to originate from the aortic leaflet at its time of maximal excursion. EPD apears to be a safe, noninvasive method to solve the problem of the origin of systolic clicks.
No takes yet. Share an insight, caveat, or question.
Veyrat et al. (1981) conducted a case report in Systolic clicks (n=2). Echo-pulsed doppler (EPD) was evaluated on Localization of the origin of systolic clicks. Echo-pulsed Doppler successfully localized the origin of systolic clicks to the prolapsed anterior tricuspid leaflet in one patient and the aortic leaflet in another.
Synapse has enriched 10 related papers. Consider them for comparative context: