Answers are grounded in this paper and cite their sources.
This study investigates nucleate boiling under subcooled forced flow conditions on aluminum using distilled water, water-50% ethylene glycol aqueous solution, and Long-Life Coolant. Bubble dynamics, surface morphology, coolant viscosity effects, and corrosion-related changes in heat transfer were analyzed. Distilled water initially showed efficient boiling, but surface oxidation reduced performance over time. Water-50% ethylene glycol aqueous solution exhibited bubble sliding, limiting vapor film formation. Long-Life Coolant’s high viscosity and hydrophobicity led to bubble stagnation and poor heat transfer. Findings emphasize the roles of coolant properties and surface degradation, suggesting that surface treatments are key to sustaining efficient boiling in long-term thermal management applications.
No takes yet. Share an insight, caveat, or question.
Yilmaz et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: