Answers are grounded in this paper and cite their sources.
Simulation study demonstrates dynamic thermometric performance across thin-film thermocouples, highlighting design factors for confined-space temperature sensing.
Transient temperature measurement in confined spaces remains a critical engineering challenge. We report the development of different types of thin-film thermocouples (TFTCs) and conducted some simulation comparisons. The static calibration shows an excellent linearity of 0.998 and a small measurement deviation of 1.13% within the temperature range of 25–200 °C. To elucidate the micro/nanoscale heat transfer mechanisms of different TFTCs, we constructed temperature-field calculations and found that the K-type TFTC has relatively limited axial heat leakage and cold-junction temperature rise under the conditions considered, with a hot-to-cold junction temperature difference of approximately 50 °C. Besides, we quantify the size effect of film thickness (from 600 to 2000 nm), demonstrating that system heat capacity and thermal leakage amplify synergistically with increasing thickness. The effects of heat-source offset and convective conditions on the sensed temperature were also investigated. This work establishes a multi-dimensional simulation framework of various types of TFTCs, which guides the material selection and engineering deployment of in-situ temperature measurement under different operational conditions.
No takes yet. Share an insight, caveat, or question.
Zhao et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: