Key result
Electrical impedance cardiography indices, specifically the Heather index and RZ time, correlated with echocardiographic wall motion score.
Why the study?
Does electrical impedance cardiography accurately reflect left ventricular function compared to echocardiography in patients with coronary artery disease?
Cross-Sectional (n=8)
Does electrical impedance cardiography accurately reflect left ventricular function compared to echocardiography in patients with coronary artery disease?
The Heather index derived from electrical impedance cardiography correlates well with echocardiographic wall motion score during dobutamine stress testing, suggesting potential utility for continuous non-invasive left ventricular performance monitoring.
Answers are grounded in this paper and cite their sources.
May support non-invasive LV monitoring in CAD; leaves open accuracy versus echocardiography pending prospective validation.
BACKGROUND: Simple, accurate, continuous non-invasive cardiac monitoring during the peri- and postoperative periods for patients at risk of cardiac failure would be very useful. Electrical impedance cardiography (EIC) has been proposed as an accurate method for non-invasive measurement of cardiac function. However, in recent years the accuracy of EIC in stroke volume (SV) measurement has been questioned and this prevented global acceptance of the method. Beside SV, EIC is capable of measuring several other left ventricular contractility indices, which are measured directly from the impedance signal. The aim of this study was to compare these variables with the echocardiographically derived left ventricular wall motion score (WMS) as the reference method. METHODS: In a group of eight coronary artery disease patients we performed a pharmacologically (dobutamine) induced stress test. Echocardiographic and impedance cardiographic recordings were performed simultaneously during four levels of dobutamine infusion. WMS was derived from the simultaneously displayed four-stage echocardiographic image. RESULTS: Analysis of variance showed that the majority of indices changed significantly during the test. Direct correlation with the wall motion score gave very satisfactory results over all stages with the RZ time (r = 0.75, P < 0.001) and Heather index (r = -0.78, P < 0.001). Other correlations were substantially lower. CONCLUSION: The Heather index has to be preferred as indicator of the left ventricular performance. Since EIC is capable of giving continuous information of the left ventricular performance, it might be a valuable method for peri- and postoperative monitoring.
No takes yet. Share an insight, caveat, or question.
Meer et al. (1999) conducted a cross-sectional in Coronary artery disease (n=8). Electrical impedance cardiography (EIC) vs. Echocardiographically derived left ventricular wall motion score (WMS) was evaluated on Correlation between EIC indices and wall motion score (r = -0.78 (Heather index), p=<0.001). Electrical impedance cardiography indices, specifically the Heather index and RZ time, correlated with echocardiographic wall motion score.
Synapse has enriched 10 related papers. Consider them for comparative context: