Key result
B-mode aortic ultrasonography closely approximated intraoperative aneurysm measurement, with 75% of measurements within 0.5 cm of true size, compared to 38% for physical exam and 44% for X-ray.
Why the study?
Does B-mode aortic ultrasonography provide more accurate measurement of aortic aneurysm size compared to physical examination and lateral roentgenography?
Observational (n=53)
Does B-mode aortic ultrasonography provide more accurate measurement of aortic aneurysm size compared to physical examination and lateral roentgenography?
Answers are grounded in this paper and cite their sources.
B-mode aortic ultrasonography provides highly accurate preoperative measurements of aortic aneurysm size, outperforming physical examination and lateral roentgenography.
In a study of 53 cases, aneurysm size was measured with the use of preoperative physical examination, lateral abdominal roentgenography, and B-mode aortic ultrasonography for comparison with direct intraoperative measurement during aneurysmectomy. Mean aneurysm diameter on the basis of physical examination overestimated aortic size by 1 cm; physical examination measurement was within 0.5 cm of true aortic size in 38% of patients and within 1 cm in 58% of patients. The lateral roentgenogram also overestimated mean aortic diameter by 1 cm and was within 0.5 cm of true aortic size in 44% of patients and within 1 cm in 72% of patients. Measurement using B-mode aortic ultrasonography closely approximated intraoperative aneurysm measurement. Measurement was identical in 34% of patients and was within 0.5 cm and 1 cm in 75% and 92% of patients, respectively. (JAMA240:1966-1968, 1978)
No takes yet. Share an insight, caveat, or question.
N. R. Hertzer (1978) conducted an observational in Aortic aneurysm (n=53). B-mode aortic ultrasonography vs. Physical examination and lateral abdominal roentgenography was evaluated on Measurement within 0.5 cm of true aortic size (intraoperative measurement). B-mode aortic ultrasonography closely approximated intraoperative aneurysm measurement, with 75% of measurements within 0.5 cm of true size, compared to 38% for physical exam and 44% for X-ray.