Key result
MDCT provides the most accurate aortic annulus measurements compared with 2D-TTE and 3D-TEE.
Why the study?
Accurate preprocedural quantification of the aortic annulus diameter is crucial for operative success in aortic valve surgery and TAVR, but the comparative accuracy of imaging methods was unclear.
Does MDCT improve the accuracy of preoperative aortic annulus measurement compared to 2D-TTE and 3D-TEE in patients undergoing open aortic valve surgery?
Observational (n=52)
Single-blind
Does MDCT improve the accuracy of preoperative aortic annulus measurement compared to 2D-TTE and 3D-TEE in patients undergoing open aortic valve surgery?
MDCT is the most accurate non-invasive imaging modality for measuring aortic annulus diameter compared to 2D-TTE and 3D-TEE, which is critical for preprocedural planning in aortic valve surgery and TAVR.
Answers are grounded in this paper and cite their sources.
MDCT may refine annulus sizing in surgical candidates; leaves open whether it improves outcomes or warrants routine adoption.
OBJECTIVE: Accurate preprocedural quantification of the aortic annulus diameter is crucial for the operative success of the aortic valve surgery and especially transcatheter aortic valve replacement (TAVR). We conducted a prospective study to compare the accuracy of preoperative aortic annulus measurements using different imaging methods and direct measurements for aortic valve surgery. METHODS: We enrolled 52 patients who underwent open aortic valve surgery between March 2012 and March 2014. Aortic annulus diameter was prospectively measured by transthoracic two-dimensional echocardiography (2D-TTE), transesophageal three-dimensional echocardiography (3D-TEE), and multi-detector computed tomography (MDCT). Imaging measurements were performed blindly by lab technicians. At surgery, the aortic annulus diameter was directly measured. RESULTS: Of the three methods, MDCT provided the smallest error in determining aortic annulus size as compared with the measurements at surgery. The limit of agreement of the aortic diameter by MDCT was smallest in the present study. CONCLUSIONS: The MDCT provided the most accurate measurement of aortic annulus diameter compared with 2D-TTE and 3D-TEE.
No takes yet. Share an insight, caveat, or question.
Tsuneyoshi et al. (2015) conducted an observational in Aortic valve disease requiring surgery (n=52). Multi-detector computed tomography (MDCT) vs. 2D-TTE and 3D-TEE was evaluated on Accuracy of aortic annulus diameter measurement compared to direct surgical measurement. Multi-detector computed tomography provided the most accurate measurement of aortic annulus diameter compared with 2D-TTE and 3D-TEE in 52 patients undergoing open aortic valve surgery.
Synapse has enriched 10 related papers. Consider them for comparative context: