This article proposes a method to jointly estimate the state of the grid-connected voltage source converter with an LCL filter and the grid inductance based on nonlinear sigma-point Kalman filter (SPKF). The estimated parameters and states are used to improve the performance of the grid-connected converter controlled with modulated model predictive control (MPC). The proposed SPKF-MPC control method does not require sensing the point of common coupling voltage. Moreover, this article proposes a novel method to enable the proposed SPKF-MPC to distinguish between the steady-state and low-voltage ride-through operation and to detect faults. Simulation results have shown good performance for the proposed SPKF-MPC during steady-state and disturbances. In addition, the proposed SPKF-MPC has demonstrated improved performance over conventional MPC, particularly in the case of grid inductance uncertainty/mismatch and weak grid conditions. Results have been validated via experimental setup, verifying the accuracy and robustness of the proposed control strategy.
No takes yet. Share an insight, caveat, or question.
M.Osman et al. (2026) studied this question.