Key result
A new venous-thrombus aspiration and autologous blood reinfusion system successfully aspirated thrombi in an in vitro model, with no significant differences in aspiration rates between catheter sizes.
Why the study?
The feasibility of a new venous-thrombus aspiration and autologous blood reinfusion system required evaluation.
A newly designed venous-thrombus aspiration and autologous blood reinfusion system demonstrated feasibility in an in vitro model.
Feasibility of new aspiration-reinfusion system shown in vitro; leaves open in vivo validation before any clinical consideration.
Purpose The aim of the study was to evaluate the feasibility of a new venous-thrombus aspiration and autologous blood (auto-blood) reinfusion system. Materials and methods We constructed the venous model from polyvinyl chloride (PVC) tubes and three-way unions using a fresh clot of chicken blood as the venous thrombus. Eight French and 12F aspiration catheters were used to aspirate the thrombus in the right–pulmonary-artery model, 8 French and 14F aspiration catheters were used in the inferior–vena cava model, and 8 French and 10F aspiration catheters were used in the left–iliofemoral-vein model. A thrombus filtration and auto-blood reinfusion bottle was used to filter the thrombus and re-infuse auto-blood. We evaluated the thrombus aspiration capability of each catheter by comparing pre-aspirated with the post-aspirated thrombus volume, and we evaluated the difference in aspiration capability between the two catheters in each model by comparing their thrombus aspiration rates. We used Student's t -test for statistical analysis. Results Differences between pre-aspirated and post-aspirated thrombus volumes for each catheter were insignificant, as were those between the thrombus aspiration rates of the two catheters in each venous model. Using the thrombus aspiration and auto-blood reinfusion system, each aspiration catheter could fluently aspirate the thrombus out of the venous model. Conclusion In this study, we designed a new venous-thrombus aspiration system. This system could be used to aspirate acute venous thrombi and re-infuse autologous blood.
No takes yet. Share an insight, caveat, or question.
Li et al. (2019) studied Venous thrombus (in vitro model). New venous-thrombus aspiration and autologous blood reinfusion system vs. Different catheter sizes (8F vs 10F, 12F, 14F) was evaluated on Thrombus aspiration capability (pre-aspirated vs post-aspirated thrombus volume) and thrombus aspiration rates (p=not significant). A new venous-thrombus aspiration and autologous blood reinfusion system successfully aspirated thrombi in an in vitro model, with no significant differences in aspiration rates between catheter sizes.