Key result
Indigo CAT RX aspiration alone achieves complete perfusion in ~86% of pre-PCI ACS patients.
Why the study?
Routine manual aspiration thrombectomy trials in ACS have reported mixed results, potentially due to decreasing vacuum power during aspiration.
Does continuous mechanical aspiration before PCI improve angiographic outcomes and safety in patients with acute coronary syndrome?
Observational (n=72)
Yes
Does continuous mechanical aspiration before PCI improve angiographic outcomes and safety in patients with acute coronary syndrome?
Continuous mechanical aspiration before PCI in ACS patients with high thrombus burden appears safe and effectively restores coronary flow.
Hypothesis-generating for pre-PCI aspiration in high-thrombus ACS; does not support practice change pending randomized trials.
Objectives Here we investigate the safety and efficacy of a continuous mechanical aspiration system when used before percutaneous coronary intervention (PCI) in patients with acute coronary syndrome (ACS). Background Historically, trials of routine manual aspiration thrombectomy in ACS patients have reported mixed results. This may be due to the technical limitations of manual aspiration, which suffers from decreasing vacuum power as aspiration is performed. Methods This is a retrospective case series of all patients treated with continuous mechanical aspiration (Indigo CAT RX Aspiration System; Penumbra Inc.) before PCI between August 2017 and July 2020 at five centers in the United States. Data regarding angiographic assessments, procedure, and safety were examined. Results Seventy‐two patients (mean age 60 ± 12.5 years, 34.7% female) with ST Elevation Myocardial Infarction (STEMI) (80.6%) or Non‐ST Elevation Myocardial Infarction (NSTEMI) (19.4%) were included. Target vessels were the right coronary (43.1%), left anterior descending (33.3%), and left circumflex (23.6%). Preprocedure, 94.4% had a high thrombus burden (thrombolysis in myocardial infarction [TIMI] thrombus grade ≥ 3). Median aspiration time was 35 s and median access‐to‐reperfusion time was 10 min. After CAT RX alone, 86.1% had complete perfusion (TIMI flow grade 3). After the procedure, 94.4% had TIMI thrombus grade <3% and 97.2% had TIMI flow grade 3. There were no cases of ischemic stroke. Cardiovascular mortality at 30 days was 1.4%. Conclusions In our initial experience, aspirating thrombus from ACS patients using the Indigo CAT RX Aspiration System before PCI was safe and effective for reducing thrombus burden and restoring flow.
No takes yet. Share an insight, caveat, or question.
Mathews et al. (2022) conducted an observational in Acute coronary syndrome (ACS) (n=72). Indigo CAT RX Aspiration System was evaluated on Complete perfusion (TIMI flow grade 3) after CAT RX alone. Continuous mechanical aspiration using the Indigo CAT RX system before PCI in ACS patients achieved complete perfusion (TIMI flow grade 3) in 86.1% of patients after aspiration alone.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: