The paper presents a discharge predictor based on known end depth in circular free overfall having positive, negative and zero slope. The discharge predictor presented herein provides direct solution without any trial and error procedure, does not require graphs for the solution and can be used for cast iron, P.V.C., galvanized iron and trowel finished cement surfaces. The reliability of the proposed predictor has been assessed by comparing the results obtained from the present predictor and from some of the available predictors such as those of King (1939), Rohwer Carl. W. (1943), Smith P. M. (1962) and Diskin M. H. (1964) using the published experimental data of Rajaratnam and Muralidhar (1964). It has been observed that the proposed predictor gives least mean percentage error of estimate and standard deviation than the other available predictors. The proposed predictor is also tested with the experimental data of Subramanya &Kumar (1993). Further verification analysis of the proposed predictor has been done for sloping channels with the available data of Rajaratnam &Murlidhar (1964).
No takes yet. Share an insight, caveat, or question.
Gupta et al. (2000) studied this question.