Why the study?
Few studies have evaluated clinical outcomes of TAVR in bicuspid aortic valve stenosis, with limited data comparing new-generation versus early-generation devices.
Population
301 consecutive patients with bicuspid AS undergoing TAVR
Comparison
Early-generation devices vs new-generation devices
Design
International multicenter registry study
Follow-up
1 year
Key result
TAVR with new-generation devices in bicuspid aortic stenosis was associated with less moderate or severe paravalvular leak (0.0% vs 8.5%, p=0.002) and higher device success than early devices.
Authors
Loading...
Observational study reveals improved device success with new-generation prostheses in bicuspid aortic valve stenosis, indicating enhanced safety.
Cohort (n=301)
Yes
Absolute Event Rate: 0% vs 8.5%
p-value: p=0.002
Yoon et al. (2016) conducted a cohort in bicuspid aortic valve stenosis (n=301). TAVR with new-generation devices vs. TAVR with early-generation devices was evaluated on Moderate or severe paravalvular leak (p=0.002). TAVR with new-generation devices in bicuspid aortic stenosis was associated with less moderate or severe paravalvular leak (0.0% vs 8.5%, p=0.002) and higher device success than early devices.