September 7, 2026Journal of the American College of CardiologyOpen Access

Transcatheter Aortic Valve Replacement With Early- and New-Generation Devices in Bicuspid Aortic Valve Stenosis

View Full Paper
Ask AI
Bookmark
Share

Why the study?

Few studies have evaluated clinical outcomes of TAVR in bicuspid aortic valve stenosis, with limited data comparing new-generation versus early-generation devices.

Population

301 consecutive patients with bicuspid AS undergoing TAVR

Comparison

Early-generation devices vs new-generation devices

Design

International multicenter registry study

Follow-up

1 year

Key result

TAVR with new-generation devices in bicuspid aortic stenosis was associated with less moderate or severe paravalvular leak (0.0% vs 8.5%, p=0.002) and higher device success than early devices.

Authors

SYSung-Han YoonTLThierry LefèvreJAJung-Ming Ahn

Discussion

Loading...

Member takes

Overview

Observational study reveals improved device success with new-generation prostheses in bicuspid aortic valve stenosis, indicating enhanced safety.

Key Points

  • To evaluate the procedural safety, efficacy, and clinical outcomes of transcatheter aortic valve replacement comparing early-generation and new-generation devices in patients with bicuspid aortic valve stenosis.
  • International multicenter registry evaluating patients with severe bicuspid aortic valve stenosis undergoing transcatheter aortic valve replacement.
  • Comparison of procedural and clinical outcomes between early-generation devices (e.g., Sapien XT, CoreValve) and new-generation devices (e.g., Sapien 3, Evolut R, Lotus).
  • Assessment of device success, significant paravalvular regurgitation, aortic root injury, and mortality at 30 days and 1 year.
  • New-generation transcatheter heart valves achieved significantly higher device success compared to early-generation devices.
  • Use of new-generation devices resulted in significantly reduced rates of moderate-to-severe paravalvular regurgitation and lower rates of aortic root injury.

Study Design

Type

Cohort (n=301)

Multicenter

Yes

PICO

P
Population
301 consecutive patients with bicuspid aortic valve stenosis undergoing TAVR, evaluated for clinical outcomes and device success.
E
Exposure / Comparator
TAVR with new-generation devices vs TAVR with early-generation devices
O
Primary Outcome
Moderate or severe paravalvular leak, p=0.002

Main Result

Absolute Event Rate: 0% vs 8.5%

p-value: p=0.002

Cite This Study

Yoon et al. (2016) conducted a cohort in bicuspid aortic valve stenosis (n=301). TAVR with new-generation devices vs. TAVR with early-generation devices was evaluated on Moderate or severe paravalvular leak (p=0.002). TAVR with new-generation devices in bicuspid aortic stenosis was associated with less moderate or severe paravalvular leak (0.0% vs 8.5%, p=0.002) and higher device success than early devices.