Key result
The APPRAISE ATP trial is designed to compare shocks-only programming versus standard therapy (ATP and shock) on time to first all-cause shock in approximately 2,600 primary prevention ICD patients.
Why the study?
The value of antitachycardia pacing in primary prevention patients receiving ICDs remains uncertain, as prior trial success may have included unnecessary therapy for self-terminating arrhythmias.
Does programming ICDs to standard therapy (ATP and shock) compared to shocks only reduce the incidence of all-cause shocks in primary prevention patients?
RCT (n=2,600)
randomized
Yes
Does programming ICDs to standard therapy (ATP and shock) compared to shocks only reduce the incidence of all-cause shocks in primary prevention patients?
Answers are grounded in this paper and cite their sources.
The APPRAISE ATP trial is designed to evaluate whether standard ICD programming with ATP and shocks reduces all-cause shocks compared to shock-only programming in primary prevention patients.
Background The value of antitachycardia pacing (ATP) in the overall cohort of primary prevention patients who receive implantable cardioverter-defibrillators (ICDs) remains uncertain. ATP success reported in prior trials potentially included a large number of patients receiving unnecessary ATP for arrhythmias that may have self-terminated owing to the prematurity of the intervention. Although some patients derive benefit from initial ATP in terminating rapid ventricular arrhythmias and thereby preventing shocks, there are limited data allowing us to identify those patients a priori . Objective The purpose of APPRAISE ATP is to understand the role of ATP in primary prevention patients currently indicated for ICD therapy in a large prospective randomized controlled trial with modern programming parameters. Methods The study is a global, prospective, randomized, multicenter clinical trial conducted at up to 150 sites globally, enrolling approximately 2600 subjects The primary endpoint of the trial is time to first all-cause shock in a 2-arm study with an equivalent study design in which the incidence of all-cause shocks will be compared between primary prevention subjects programmed with shocks only vs subjects programmed to standard therapy (ATP and shock). Results An Electrogram and Device Interrogation Core Laboratory will review interrogation data to determine primary endpoints that occur in APPRAISE ATP. Their decisions are based on independent physician review of the data from device interrogation. Conclusion The ultimate purpose of the study is to aid clinicians in the selection of ICD technologies based on hard endpoint evidence across the spectrum of indications for primary prevention implantation.
No takes yet. Share an insight, caveat, or question.
Schuger et al. (2021) conducted an RCT in Primary prevention patients indicated for ICD therapy (n=2,600). Shocks only programming vs. Standard therapy (ATP and shock) was evaluated on Time to first all-cause shock. The APPRAISE ATP trial is designed to compare shocks-only programming versus standard therapy (ATP and shock) on time to first all-cause shock in approximately 2,600 primary prevention ICD patients.
Synapse has enriched 10 related papers. Consider them for comparative context: