Key result
Intraoperative transesophageal echocardiography effectively assessed prosthetic stentless valve function, with 83.7% of implants showing low gradients and 15.3% exhibiting moderate gradients.
Why the study?
Does intraoperative transesophageal echocardiography (TEE) effectively assess prosthetic stentless valve function in patients undergoing aortic valve replacement?
Observational (n=26)
Does intraoperative transesophageal echocardiography (TEE) effectively assess prosthetic stentless valve function in patients undergoing aortic valve replacement?
Intraoperative TEE is effective in assessing prosthetic stentless valve function, demonstrating predominantly low gradients and minimal regurgitation post-implantation.
Answers are grounded in this paper and cite their sources.
Supports intraoperative TEE for stentless valve assessment in AVR; leaves open randomized validation of outcomes.
Background: The aim of this study was to assess the utility of intraoperative transesophageal echocardiography (TEE) in the evaluation of patients undergoing aortic valve replacement with the CryoLife-O'Brien® (CLOB) Stentless Porcine Aortic Bioprosthesis. Methods: Between May 1994 and March 1995, 26 patients (15 men, mean age 68.4±10.78 years) had a CLOB valve in the aortic position. Transprosthetic gradients and valve regurgitation were detected by intraoperative TEE. Prosthetic regurgitation and transvalvular gradients were evaluated at six-month intervals using transthoracic echo-Doppler (TTE). Results: The majority of implants resulted in low gradients (83.7%), with only four patients exhibiting a moderate gradient (15.3%). Color flow Doppler imaging showed central aortic regurgitation in only four of 25 patients (trivial, n = 4; mild, n = 1). There was one paravalvular leak (trivial. n= 1). At follow-up examination (mean 37±12 months), 24 of 25 patients exhibited low mean gradients (7.25±2.81 mmHg). At follow-up one patient who had low velocities in the LVOT at perioperative evaluation exibited a moderate gradient (45 mmHg) with an effective orifice area of 0.8–0.9 cm2. Conclusions: Intraoperative TEE was effective in assessing prosthetic stentless valve function.
No takes yet. Share an insight, caveat, or question.
Morocutti et al. (2002) conducted an observational in Aortic valve replacement (n=26). Intraoperative transesophageal echocardiography (TEE) was evaluated on Transprosthetic gradients and valve regurgitation. Intraoperative transesophageal echocardiography effectively assessed prosthetic stentless valve function, with 83.7% of implants showing low gradients and 15.3% exhibiting moderate gradients.
Synapse has enriched 10 related papers. Consider them for comparative context: