A simple, self‐aligning, uniaxial test firtiire has been developed for testing ceramics. The primary emphasis is placed on a simple specimen geometry and test procedure. The strain gage measurements on α‐Sic and steel specimens indicate very good uniformity in the tensile stresses (with variation less than 1%) across the cross section. The tensile testing of SiC and SiC/TiB 2 composites exhibits 55% and 79% failures, respectively, in the gage section with possible further improvements. Average tensile strength values of 160 and 202 MPa were obtained for α‐SiC and SiC/TiB 2 respectively.
No takes yet. Share an insight, caveat, or question.
Seshadri et al. (1987) studied this question.