Key result
Use of proximal protection (OR 3.06) and distance from carotid bifurcation to maximum stenotic lesion ≤10 mm (OR 3.4) were independent risk factors for developing hypotension requiring vasopressors after carotid artery stenting.
Why the study?
Does postprocedural hypotension after carotid artery stenting increase the risk of major adverse events in patients with carotid artery stenosis?
Observational (n=118)
No
Does postprocedural hypotension after carotid artery stenting increase the risk of major adverse events in patients with carotid artery stenosis?
Answers are grounded in this paper and cite their sources.
Postprocedural hypotension after carotid artery stenting is common and predicted by the absence of baseline hypertension, use of proximal protection, and lesion proximity to the bifurcation, but it does not significantly increase major adverse events when promptly managed.
A significant controversy exists regarding the clinical impact of hemodynamic depression on major adverse events after carotid artery stenting (CAS). The purpose of this study was to evaluate the incidence, predictors, and clinical significance of hypotension after CAS. A total of 118 cases of carotid artery stenosis were treated with CAS. Hypotension was defined as sustained systolic blood pressure <80 mmHg and requiring intravenous administration of vasopressor to maintain adequate systolic blood pressure after the procedure. Baseline characteristics, procedural characteristics, and periprocedural major adverse events were retrospectively compared between postprocedural hypotension group and non-hypotension group. Morphological and procedural characteristics were not significantly different between the two groups. Periprocedural major adverse events, presence of new ischemic lesions, and number of new ischemic lesions were not significantly different between the two groups (P = 1, P = 0.36, P = 0.68). Hypertension was an independent protective factor (P = 0.037), and use of proximal protection and the distance from carotid bifurcation to maximum stenotic lesion ≤ 10 mm were independent risk factors for developing hypotension after CAS (P = 0.034, P = 0.027). There was no significant relationship between hypotension after CAS and major adverse events in this study. Maintenance of periprocedural adequate cerebral perfusion is thought to be important to prevent ischemic complications due to hypotension after CAS, especially in these cases.
No takes yet. Share an insight, caveat, or question.
Nanto et al. (2017) conducted an observational in Carotid artery stenosis (n=118). Proximal protection vs. Non-proximal protection was evaluated on Postprocedural hypotension requiring vasopressor (OR 3.06, 95% CI 1.09-8.62, p=0.034). Use of proximal protection (OR 3.06) and distance from carotid bifurcation to maximum stenotic lesion ≤10 mm (OR 3.4) were independent risk factors for developing hypotension requiring vasopressors after carotid artery stenting.
Synapse has enriched 10 related papers. Consider them for comparative context: