Key result
Remote monitoring in adults with transposition of the great arteries after atrial switch repair reduced the mean detection time of arrhythmias to 2.4 days compared to 108.5 days with conventional follow-up, advancing clinical decision-making by a mean of 77.5 days.
Why the study?
Does a remote monitoring system improve the early recognition and treatment of critical arrhythmias in adults with transposition of the great arteries after atrial switch operation?
Cohort (n=32)
Yes
Does a remote monitoring system improve the early recognition and treatment of critical arrhythmias in adults with transposition of the great arteries after atrial switch operation?
Remote monitoring in adults with transposition of the great arteries after atrial switch repair enables significantly earlier detection and treatment of critical arrhythmias compared to conventional follow-up.
May support earlier arrhythmia detection in TGA post-atrial switch; leaves open outcome impact in prospective trials.
BACKGROUND: Adults with transposition of the great arteries (TGA) after atrial switch repair have an increased risk for arrhythmia and sudden cardiac death. We analyzed whether a remote monitoring (RM) system as part of an implantable cardiac device contributes to timely recognition and improved treatment of critical arrhythmias in these patients. METHODS AND RESULTS: All consecutive TGA patients (n=11) requiring a pacemaker or cardiac resynchronization therapy with or without implantable cardioverter defibrillator between 2008 and 2011 were included. RM-detected arrhythmia, abnormality of device integrity and reaction time from event transmission until acknowledgement via email and clinical decision making were analyzed and compared to a control group (n=21). In 10 patients (91%) 17 arrhythmias were detected, 8 patients (80%) indicated no symptoms. In the RM group time interval from transmission to acknowledgement was 2.4 days (range, 0-4.5 days). Clinical decision-making was advanced by a mean of 77.5 days (range, 10-197 days) compared with conventional follow-up and identified adaption of anti-arrhythmic medication in 8, electrical cardioversion in 2, overdrive pacing in 1 and radiofrequency ablation in 2 patients. A coronary sinus lead fracture was identified in 1 patient followed by successful replacement. CONCLUSIONS: RM enables early detection of tachyarrhythmia followed by optimization of medical treatment and potentially life-saving anti-tachycardic intervention in adults after atrial repair of TGA.
No takes yet. Share an insight, caveat, or question.
Nagel et al. (2013) conducted a cohort in Transposition of the great arteries after atrial switch operation (n=32). Remote monitoring system vs. Conventional cardiac device follow-up was evaluated on Detection time of arrhythmias (days). Remote monitoring in adults with transposition of the great arteries after atrial switch repair reduced the mean detection time of arrhythmias to 2.4 days compared to 108.5 days with conventional follow-up, advancing clinical decision-making by a mean of 77.5 days.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: