Key result
Oral treatment with the endothelin receptor antagonist BSF 208075 significantly reduced neointimal thickness and increased total coronary artery lumen in a pig model of stent-induced restenosis.
Why the study?
Does oral dosing of the endothelin receptor antagonist BSF 208075 reduce restenosis in a pig model of stent-induced restenosis?
RCT (n=37)
randomly allocated
Does oral dosing of the endothelin receptor antagonist BSF 208075 reduce restenosis in a pig model of stent-induced restenosis?
Answers are grounded in this paper and cite their sources.
Oral administration of the endothelin receptor antagonist BSF 208075 significantly reduced neointimal thickness and increased coronary artery lumen in a pig model of stent-induced restenosis, demonstrating an antiproliferative effect.
The aim of the present study was to test whether oral dosing of an endothelin (ET) receptor antagonist was able to reduce restenosis in the model of stent-induced restenosis. After pigs underwent coronary artery catheterization they were randomly allocated either to controls or to treatment with the ET receptor antagonist BSF 208075. Thirty-seven pigs underwent percutaneous transluminal coronary angioplasty plus stent implantation; seven animals died of ventricular fibrillation due to procedure-related myocardial ischaemia. From the 30 surviving animals coronary arteries were sampled after 6 weeks of oral treatment with 10 mg/kg/day BSF 208075 or vehicle and histologically evaluated. Stent implantation had no effect on total coronary artery diameter, and media thickness was virtually identical in the two groups. However, neointimal thickness in the group treated with the ET receptor antagonist was significantly reduced, resulting in a significantly larger total coronary artery lumen in the treated group. As in the setting of stent implantation neither 'recoil' nor scar-related vascular remodelling can occur, this result allows the conclusion of a significant antiproliferative effect of ET receptor antagonism in pig coronary arteries.
No takes yet. Share an insight, caveat, or question.
Michael Kirchengast (2001) conducted an RCT in Stent-induced restenosis (n=37). BSF 208075 (endothelin receptor antagonist) vs. Vehicle/controls was evaluated on Neointimal thickness and total coronary artery lumen. Oral treatment with the endothelin receptor antagonist BSF 208075 significantly reduced neointimal thickness and increased total coronary artery lumen in a pig model of stent-induced restenosis.
Synapse has enriched 10 related papers. Consider them for comparative context: