Answers are grounded in this paper and cite their sources.
The Perfobond Leiste (PBL) shear connector is widely adopted in steel-concrete composite structures because of its superior mechanical interlocking and efficient force transfer characteristics. The previous studies sufficiently investigated experimentally the shear response of PBL, considering various connection parameters. However, the influence of concrete confinement, specifically due to surrounding concrete volume and shear reinforcement, on internal fracture mechanisms remains understood. Accordingly, present research deals with the numerical investigation of a single PBL shear connector employing the coupled Rigid Body Spring Model (RBSM) and the nonlinear solid Finite Element Method (FEM), revealing the detailed fracture process subjected to various confinement levels imparted by adjoining concrete. The simulation results demonstrate a consistent increase in shear capacity with enhanced concrete confinement and show that the increased size of the surrounding concrete blocks led to an enhancement in the shear strength of the concrete inside the dowel. The specimen subjected to increased confinement exhibited the highest shear strength, accompanied by a transition of shear failure into splitting. Furthermore, numerical simulations highlighted that the shear stirrups in the side concrete blocks reproduced the enhancement of shear capacity and ductility and captured shear failure behavior instead of a splitting failure.
No takes yet. Share an insight, caveat, or question.
Karam et al. (2026) studied this question.