Answers are grounded in this paper and cite their sources.
This paper presents the design, fabrication, and performance evaluation of a biocompatible piezoelectric membrane actuator (PMA) using polyvinylidene fluoridetrifluoroethylene (PVDF-TrFE). Electrode structure optimization was verified by a finite element method simulation software. Fabrication was done utilizing only standard microfabrication techniques. 1-μm-thick membrane and 1.5-μm-thick actuator layers were formed by spin coating using PVDF-TrFE. The surface roughness of the fabricated film was measured as 7.9 nm using a tabletop atomic force microscope (AFM) and remnant polarization at 200 V was measured as 5.38 μC/cm2. Deflection measurements were performed with an Al coated tipless AFM probe using a precision nano displacement system, which consists of a ferroelectric tester, a table top AFM, and a computer. A 432 nm displacement was obtained at 9 V under non-resonant conditions from a PMA with 2250 μm diameter. Since all moving structures were fabricated from a polymer material, high displacements could be obtained without fracture. The results demonstrated that the proposed PMA can be a good candidate for membrane type micropumps, especially to be used in biomedical applications, where low driving voltage and biocompatibility are required.
No takes yet. Share an insight, caveat, or question.
Yildirim et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: