We precisely measure the depth profiles of 50–200 keV 18O+ implanted into Si and SiO2 by secondary ion mass spectrometry (SIMS) and then best-fit the on. The O-profiles derived from the RBS analysis are compared with those calculated by the extended TRIM. The present analysis revealed that the O-atoms implanted at 550° C migrated toward the surface before reaching the stoichiometry ( SiO2). The diffusion coefficient was estimated to be about 1×10-14 cm2/ s, which was about 2 orders of magnitude larger than the value for 16O in crystalline Si at 550° C. This is possibly due to the induced dense defects distributed from the mean depth of 16O toward the surface (enhanced diffusion).