Key result
Implantation of defibrillators under local anesthetic and conscious sedation was safe, with 0 deaths or tracheal intubations, and acceptable, with only 3.8% declining a repeat procedure.
Why the study?
Is implantation of defibrillators under local anesthetic and conscious sedation safe and acceptable to patients?
Observational (n=500)
Yes
Is implantation of defibrillators under local anesthetic and conscious sedation safe and acceptable to patients?
Implantation of defibrillators under local anesthetic and conscious sedation is safe and highly acceptable to patients, indicating that general anesthesia is not routinely required.
Supports local anesthesia with sedation for defibrillator implantation in selected patients; leaves open need for randomized confirmation of safety and acceptability.
BACKGROUND: Implantation and testing of implantable defibrillators (ICDs) using local anesthetic and conscious sedation is widely practiced; however, some centers still use general anesthesia. We assessed safety and patient acceptability for implantation of defibrillators using local anesthetic and conscious sedation. METHODS: The records of 500 consecutive device implants from two UK cardiac centers implanted under local anesthetic and conscious sedation from January 1996 to December 2004 were reviewed. Procedure time, left ventricular ejection fraction (LVEF) sedative dosage (midazolam), analgesic dosage (fentanyl or diamorphine), requirement for drug reversal, and respiratory support were recorded. Patient acceptability of the procedure was also assessed. RESULTS: Of 500 implants examined, 387 were ICDs, 88 were biventricular ICDs, and 25 were generator changes. Patients with biventricular-ICDs had significantly longer (mean +/- SD) procedure times 129.7 +/- 7.6 minutes versus 63.3 +/- 32.3 minutes; P < 0.0001 and lower LVEF 24.4 +/- 8.4% versus 35.7 +/- 15.4%; P < 0.0001. There were no differences in the doses (mean +/- SD) of midazolam 8.9 +/- 3.5 mg versus 8.0 +/- 3.1 mg; P = NS, diamorphine 4.3 +/- 2.0 mg versus 3.8 +/- 1.7 mg; P = NS or fentanyl 94.4 +/- 53.7 mcg versus 92.2 +/- 48.6 mcg; P = NS, between the two groups. There were no deaths or tracheal intubations in either group. Acceptability was available for 373 of 500 (75%) patients, 41 of 373 (11%) described "discomfort," but from these 41 patients only 14 of 373 (3.8%) declined a second procedure under the same conditions. CONCLUSIONS: Implantation of defibrillators under local anesthetic and sedation is safe and acceptable to patients. General anesthesia is no longer routinely required for implantation of defibrillators.
No takes yet. Share an insight, caveat, or question.
Fox et al. (2007) conducted an observational in Patients requiring implantable defibrillators (n=500). Local anesthetic and conscious sedation was evaluated on Safety (deaths, tracheal intubations) and patient acceptability. Implantation of defibrillators under local anesthetic and conscious sedation was safe, with 0 deaths or tracheal intubations, and acceptable, with only 3.8% declining a repeat procedure.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: