Key result
The novel fluorocopolymer-coated paclitaxel-eluting stent significantly inhibited neointimal proliferation compared to bare metal stents at 30 and 90 days in a porcine model, with similar healing.
Why the study?
Does a fluorocopolymer-coated nitinol paclitaxel-eluting stent inhibit neointimal proliferation compared to bare metal stents in a porcine iliofemoral model?
Does a fluorocopolymer-coated nitinol paclitaxel-eluting stent inhibit neointimal proliferation compared to bare metal stents in a porcine iliofemoral model?
Answers are grounded in this paper and cite their sources.
A novel fluorocopolymer-coated paclitaxel-eluting stent demonstrated consistent drug release and significantly inhibited neointimal proliferation compared to bare metal stents in a preclinical porcine model.
AIMS: Our aim was to evaluate arterial responses to paclitaxel and a novel fluorocopolymer-coated nitinol low-dose paclitaxel-eluting stent (FP-PES). METHODS AND RESULTS: Human smooth muscle cell (SMC) migration was assessed after exposure to paclitaxel in vitro. For pharmacokinetics and vascular response, FP-PES or bare metal stents (BMS) were implanted in porcine iliofemoral arteries. Paclitaxel significantly inhibited human coronary and femoral artery SMC migration at doses as low as 1 pM. Inhibition was significantly greater for femoral compared with coronary artery SMCs from 1 pM to 1 μM. Pharmacokinetics showed consistent paclitaxel release from FP-PES over the study duration. The peak arterial wall paclitaxel level was 3.7 ng/mg at 10 days, with levels decreasing to 50% of peak at 60 days and 10% at 180 days. Paclitaxel was not detected in blood or remote organs. Arteriogram and histomorphometry analyses showed FP-PES significantly inhibits neointimal proliferation versus BMS at 30 and 90 days. Re-endothelialisation scores were not different between groups. CONCLUSIONS: Paclitaxel affected femoral artery SMC migration at lower concentrations and to a greater degree than it did coronary artery SMCs. The novel FP-PES used in this preclinical study demonstrated a vascular healing response similar to BMS, while significantly inhibiting neointimal formation up to 90 days.
No takes yet. Share an insight, caveat, or question.
Hou et al. (2016) studied Neointimal proliferation. Fluorocopolymer-coated nitinol low-dose paclitaxel-eluting stent (FP-PES) vs. Bare metal stents (BMS) was evaluated on Neointimal proliferation and SMC migration. The novel fluorocopolymer-coated paclitaxel-eluting stent significantly inhibited neointimal proliferation compared to bare metal stents at 30 and 90 days in a porcine model, with similar healing.