This article presents a control technique to improve the input current quality of single-phase pulsewidth modulation boost rectifiers operating in discontinuous conduction mode (DCM). Conventional DCM boost rectifiers rely solely on output voltage regulation, which is attractive for low-power applications (up to 500 W) due to their simplicity and low cost. However, even when an input LC filter is employed, the input current typically exhibits significant third-harmonic distortion and a poor power factor. Existing solutions to address this limitation often require additional sensors or operation in critical conduction mode with variable switching frequency. In contrast, the proposed method exploits the inherent output voltage ripple as a control signal, eliminating the need for extra sensors while maintaining constant switching frequency operation. Experimental results obtained from a 500 W prototype operating at 80 kHz with a 400 V output voltage demonstrate that the proposed technique reduces the input current total harmonic distortion (THD) from approximately 30% to below 5%. The performance was experimentally verified for input voltages ranging from 100 to 240 V ᵣₘₛ and load conditions from 100 to 500 W. For load levels between 300 and 500 W, the input current THD remained below 5%, while maintaining a fixed predefined controller gain over the evaluated operating range, demonstrating satisfactory performance over a wide operating range while preserving implementation simplicity.