Key result
Modified distal end side-to-side anastomosis for size mismatched sequential CABG improved anastomotic flow but did not reduce in-hospital MI.
Why the study?
Caliber mismatch between sequential grafts and target coronaries in CABG diminishes anastomosis quality, prompting the introduction of a modified distal end side-to-side anastomosis.
Does modified distal end side-to-side (deSTS) anastomosis improve intraoperative flow dynamics and reduce adverse events compared to classic distal end end-to-side (deETS) anastomosis in patients undergoing off-pump CABG with size mismatched grafts and coronaries?
Cohort (n=185)
Does modified distal end side-to-side (deSTS) anastomosis improve intraoperative flow dynamics and reduce adverse events compared to classic distal end end-to-side (deETS) anastomosis in patients undergoing off-pump CABG with size mismatched grafts and coronaries?
Modified distal end side-to-side anastomosis improves intraoperative flow dynamics and may reduce long-term adverse events in off-pump CABG patients with size-mismatched grafts.
Answers are grounded in this paper and cite their sources.
deSTS anastomosis was associated with better flow and fewer long-term events versus deETS; leaves open need for randomized trials before practice change.
Introduction The distal end anastomosis is critical to the entire sequential grafts in coronary artery bypass grafting (CABG), but caliber mismatch diminishes the quality of the anastomosis. We aimed to introduce a modified distal end side-to-side (deSTS) anastomosis to handle the size mismatch and compared with classic distal end end-to-side (deETS) anastomosis. Methods From January 2014 to December 2018, 185 patients who underwent off-pump CABG with size mismatched sequential vein grafts (≥3.5 mm) and target coronaries (1.0–1.5 mm) at the distal end anastomoses were included. We retrospectively reviewed the data of the patients, perioperative and follow-up outcomes were analyzed. Results The deSTS group ( n = 67) showed higher anastomotic flow (19.8 ± 8.0 vs 14.9±6.8 mL/min; p < 0.001) and lower pulsatility index (2.7 ± 0.8 vs 3.2 ± 1.0; p = 0.001) than the deETS group ( n = 118). Higher incidence of in-hospital myocardial infarction (MI) was found in the deETS group but without significant difference (9.0% vs. 15.3%; p = 0.220). Kaplan-Meier analysis illustrated a relatively lower MI and major adverse cardiovascular and cerebrovascular events (MACCE) incidence in the deSTS group, and the deSTS group was associated with a reduction in long-term death, MI and MACCE in the adjusted Cox regression model. In addition, relatively higher graft patency was found in the deSTS group. Conclusions The deSTS anastomosis showed superiority in solving size mismatch in sequential CABG, including better intraoperative flow dynamics, ideal long-term graft patency and reduced the incidence of perioperative and follow-up adverse events especially in MI.
No takes yet. Share an insight, caveat, or question.
Wei et al. (2022) conducted a cohort in Patients undergoing off-pump CABG with size mismatched sequential vein grafts and target coronaries (n=185). Modified distal end side-to-side (deSTS) anastomosis vs. Classic distal end end-to-side (deETS) anastomosis was evaluated on in-hospital myocardial infarction (MI) (p=0.220). Modified distal end side-to-side anastomosis for size mismatched sequential CABG improved anastomotic flow but did not reduce in-hospital MI.