Key result
Off-pump CABG was associated with lower mean graft flow and higher pulsatility index compared to conventional on-pump CABG.
Why the study?
Does off-pump CABG compared to on-pump CABG affect intraoperative conduit flow in patients requiring coronary artery bypass surgery?
Cohort (n=60)
Does off-pump CABG compared to on-pump CABG affect intraoperative conduit flow in patients requiring coronary artery bypass surgery?
Off-pump CABG is associated with lower mean graft flow and higher pulsatility index compared to conventional on-pump CABG, raising potential concerns about long-term graft patency.
Answers are grounded in this paper and cite their sources.
TTFM may aid intraoperative graft assessment in CABG; leaves open validation of flow norms in larger on- vs off-pump comparisons.
Background: Patent bypass grafts are fundamental to successful coronary artery bypass grafting. We studied the use of transit-time flow measurement to determine its ability to detect technical errors in grafts, to measure the mean flow norms, and to compare flow in both on-pump and off-pump CABG procedures.Aim of Study: To compare conduit flow in a standardized type of CABG and OPCAB using the Left Internal Mammary Artery (LIMA) and vein grafts.Patients and Methods: This study was conducted on 60 patients requiring coronary artery bypass surgery classified into 2 equal groups:•Group A: (Conventional CABG), who were approached through on pump CABG.•Group B: (OPCAB), whom approached without cardiopul-monary bypass machine.Results: There was no statistical difference between the two groups in baseline pre-operative characteristics regarding their age, sex, NYHA class and EF%.In Group (A), the MGF was (39.51±5.26) and PI values were (2.33±0.64). While in Group (B), the MGF was (32.71± 6.47) and PI measurements were (2.71±1.22). The MGF for the occluded grafts in Group A was (14.33±3.21) ml min and (12.75±2.87) in Group B (p=.522). The corresponding PI values were (8.03±1.0) for Group A and (8.85±1.67) for Group B (p=0.489).Conclusions: TTFM technique is a highly valuable equip-ment. Mean flow is lower in the OPCAB group with higher pulsatility index than the conventional CABG group, which raises suspicion about the long term patency of OPCAB grafts.
No takes yet. Share an insight, caveat, or question.
SHAFIK et al. (2018) conducted a cohort in Coronary artery disease requiring bypass surgery (n=60). Off-pump CABG (OPCAB) vs. On-pump CABG (Conventional CABG) was evaluated on Mean graft flow (MGF). Off-pump CABG was associated with lower mean graft flow and higher pulsatility index compared to conventional on-pump CABG.
Synapse has enriched 10 related papers. Consider them for comparative context: