This is the authors' abstract. We don't add key points for this paper.
NbNbOxPb tunnel junctions of cross-line type with tunnel areas of 10 × 10 μm2 are investigated. The niobium base electrodes are annealed differently. The temperature dependence of the effective niobium energy gap and the critical Josephson current are calculated and compared with the BCS curves. The deviation of the experimentally determined values is caused by a proximity layer. With a proximity-effect model good agreement between the calculated and the experimentally determined values is realized. The parameters of the proximity layer are in qualitative agreement with AES investigations of the niobium base electrodes.