Key result
The proposed wavelet-based linear prediction coding scheme achieved high-quality ECG approximation at an average rate of 180 b/s, keeping the diagnostically crucial QRS region free of maximal error.
Answers are grounded in this paper and cite their sources.
A novel wavelet-based linear prediction coding scheme for ECG achieves high compression (180 b/s) while preserving the diagnostic quality of the QRS complex.
This paper presents a novel coding scheme for electrocardiogram (ECG). Following beat delineation, the periods of the beats are normalized by multirate processing. After amplitude normalization, discrete wavelet transform is applied to each beat. Due to the period and amplitude normalization, the wavelet transform coefficients bear a high correlation across beats at identical locations. To increase the compression ratio, the residual sequence obtained after linear prediction of the significant wavelet coefficients is transmitted to the decoder. The difference between the actual period and the mean beat period, and that between the actual scale factor and the average amplitude scale factor are also transmitted for each beat. At the decoder, the inverse wavelet transform is computed from the reconstructed wavelet transform coefficients. The original amplitude and period of each beat are then recovered. The approximation achieved, at an average rate of 180 b/s, is of high quality. We have evaluated the normalized maximum amplitude error and its position in each cycle, in addition to the normalized root mean square error. The significant feature of the proposed technique is that, while the error is nearly uniform throughout the cycle, the diagnostically crucial QRS region is kept free of maximal reconstruction error.
No takes yet. Share an insight, caveat, or question.
Ramakrishnan et al. (1997) studied Electrocardiogram (ECG) signal processing. Wavelet-based linear prediction coding scheme was evaluated on Normalized maximum amplitude error, its position in each cycle, and normalized root mean square error. The proposed wavelet-based linear prediction coding scheme achieved high-quality ECG approximation at an average rate of 180 b/s, keeping the diagnostically crucial QRS region free of maximal error.
Synapse has enriched 10 related papers. Consider them for comparative context: