January 1, 2009Vojnosanitetski pregledOpen Access

Preoperative echocardiographic parameters influencing quality of life five years after coronary artery bypass graft surgery

View Full Paper
Ask AI
Bookmark
Share

Why the study?

Do preoperative echocardiographic parameters predict quality of life 5 years after coronary artery bypass graft surgery?

Population

180 patients who underwent complete myocardial revascularization without comorbidities, mean age 57.8, 79.4%…

Design

Cohort

Follow-up

60 months

Key result

Preoperative echocardiographic parameters, including left ventricle end-diastolic diameter (cut-off 54.5 mm, RR 1.386), significantly predicted quality of life 5 years after coronary artery bypass graft surgery.

Authors

MZMarija ZdravkovićMRMiljko RistićNMNataša Milić

Discussion

Loading...

Member takes

Overview

May inform preoperative QoL counseling after CABG; hypothesis-generating, needs prospective validation before practice change.

Study Design

Type

Cohort (n=449)

Structured PICO

Do preoperative echocardiographic parameters predict quality of life 5 years after coronary artery bypass graft surgery?

P
Population
449 patients undergoing complete coronary artery bypass graft surgery without comorbidities, with a subgroup of 180 patients followed for 60 months to evaluate quality of life.
E
Exposure
Preoperative echocardiographic assessment
O
Outcome
Quality of life evaluated using SF-36 questionnaire at 60 monthspatient reported

Main Result

Relative Risk: 1.386

p-value: p=<0.001

Preoperative echocardiographic parameters such as left ventricular dimensions and ejection fraction strongly predict long-term quality of life after coronary artery bypass graft surgery.

Cite This Study

Zdravković et al. (2009) conducted a cohort in Coronary artery bypass graft surgery (n=449). Preoperative echocardiographic parameters (e.g., left ventricle dilatation, low ejection fraction) vs. Normal echocardiographic parameters was evaluated on Prediction of optimal quality of life (left ventricle EDD cut-off 54.5 mm) (RR 1.386, p=<0.001). Preoperative echocardiographic parameters, including left ventricle end-diastolic diameter (cut-off 54.5 mm, RR 1.386), significantly predicted quality of life 5 years after coronary artery bypass graft surgery.