This paper describes the cogging torque of the permanent magnet synchronous (PM) motors due to the magnetic anisotropy of motor core. The cogging torque due to the magnetic anisotropy is calculated by the finite element method using two kinds of modeling methods: one is the 2D magnetization property method, and the other is the conventional method. As a result, the PM motors with parallel laminated core show different cogging torque waveform from the PM motors with the rotational laminated core due to the influence of the magnetic anisotropy. The amplitudes of the cogging torque are different depending on the modeling methods in the region of high flux density.
No takes yet. Share an insight, caveat, or question.
Yamaguchi et al. (2004) studied this question.
Synapse has enriched 2 closely related papers on similar clinical questions. Consider them for comparative context: