Key result
AVA ≤1.0 cm² linked to ~66% higher mortality only when transvalvular flow rate exceeds median.
Why the study?
Aortic valve area can be underestimated at low transvalvular flow rate, but the impact of flow rate on the prognostic value of AVA ≤1.0cm2 was unknown.
Does transvalvular flow rate modify the prognostic value of aortic valve area ≤1.0cm2 for mortality in patients with moderate or severe aortic stenosis?
Cohort (n=1,131)
Yes
Does transvalvular flow rate modify the prognostic value of aortic valve area ≤1.0cm2 for mortality in patients with moderate or severe aortic stenosis?
Answers are grounded in this paper and cite their sources.
Captured external expert commentary on this paper, strongest first. Original sources are linked where available.
“It is vital to know when the right time to perform valve replacement is because too early and you subject the patient to the risks of a procedure or operation unnecessarily, too late and the patient is at risk of death from the valve disease before the replacement occurs.”
Transvalvular flow rate determines the prognostic value of aortic valve area in aortic stenosis, demonstrating that AVA measured at low flow rates is not a reliable prognostic or diagnostic marker for truly severe disease.
Background: Aortic valve area (AVA) ≤1.0cm2 is a defining characteristic of severe aortic stenosis (AS). AVA can be underestimated at low transvalvular flow rate. Yet, the impact of flow rate on prognostic value of AVA ≤1.0cm2 is unknown and is not incorporated into AS assessment. Objectives: We aimed to evaluate the effect of flow rate on prognostic value of AVA in AS. Methods: We studied 1,131 patients with moderate or severe AS and complete clinical follow up as part of a longitudinal database. We evaluated effect of flow rate (ratio of stroke volume to ET) on prognostic value of AVA ≤1.0cm2 for time to death, adjusting for confounders. Sensitivity analysis was performed to identify the optimal cutoff for prognostic threshold of AVA. We validated findings in a separate external longitudinal cohort of 939 patients. Results: Flow rate had a significant effect on prognostic value of AVA. AVA ≤1.0cm2 was not prognostic for mortality (p=0.15) if AVA was measured at flow rates below median (≤242mL/s). In contrast, AVA ≤1.0cm2 was highly prognostic for mortality (p=0.003) if AVA was measured at flow rates above median (>242mL/s). Findings were irrespective of multivariable adjustment for age, sex and SAVR/TAVR (as time-dependent covariates), comorbidities, medications and echocardiographic features. AVA ≤1.0cm2 was also not an independent predictor of mortality below median flow rate in the validation cohort. The optimal flow rate cutoff for prognostic threshold was 210mL/s. Conclusions: Transvalvular flow rate determines prognostic value of AVA in AS. AVA measured at low flow rate is not a good prognostic marker and therefore not a good diagnostic marker for truly severe AS. Flow rate assessment should be incorporated into clinical diagnosis, classification and prognosis of AS.
No takes yet. Share an insight, caveat, or question.
Namasivayam et al. (2020) conducted a cohort in Aortic Stenosis (n=1,131). Aortic valve area ≤1.0cm2 at transvalvular flow rate >242mL/s vs. Aortic valve area >1.0cm2 at transvalvular flow rate >242mL/s was evaluated on Time to death (all-cause mortality) (HR 1.66, 95% CI 1.19-2.33, p=0.003). Aortic valve area ≤1.0cm2 was highly prognostic for mortality when measured at a transvalvular flow rate above the median, but not when measured at a flow rate below the median.