Key result
Serial Doppler echo detects acute cardiac rejection with ~88% sensitivity using pressure half-time changes.
Why the study?
The utility of serial Doppler echocardiography for evaluating left ventricular filling changes associated with acute cardiac allograft rejection required assessment.
Does serial Doppler echocardiographic evaluation of left ventricular diastolic filling accurately detect acute cardiac allograft rejection compared with endomyocardial biopsy in orthotopic cardiac transplant recipients?
Observational (n=55)
Does serial Doppler echocardiographic evaluation of left ventricular diastolic filling accurately detect acute cardiac allograft rejection compared with endomyocardial biopsy in orthotopic cardiac transplant recipients?
Answers are grounded in this paper and cite their sources.
Serial Doppler echocardiographic measurement of left ventricular diastolic function, particularly a 20% decrease in pressure half-time, provides high sensitivity (88%) and specificity (87%) for the noninvasive early detection of acute cardiac allograft rejection.
To evaluate the changes in left ventricular filling associated with acute cardiac rejection, serial Doppler echocardiographic examinations were prospectively performed on the same day as endomyocardial biopsy in 55 consecutive patients who successfully underwent orthotopic transplantation and were free of a previous episode of rejection. On average, 8.6 Doppler studies per patient were performed within a 6 month period after transplantation. Recordings of mitral flow were made with pulsed Doppler and two-dimensional echocardiography from an apical four chamber view; isovolumic relaxation time, peak early mitral flow velocity and pressure half-time were measured. The patients were classified into two groups on the basis of the histopathologic findings: group I (25 patients with at least one episode of mild or moderate rejection) and group II (30 patients without rejection). In group I, rejection was associated with a significant decrease of isovolumic relaxation time (p less than 0.005) and especially pressure half-time (p less than 0.0005) with no change in heart rate and peak early mitral flow velocity. In group II, Doppler indexes remained unchanged. These changes were not associated with alterations in left ventricular systolic function assessed by echocardiography. Isovolumic relaxation time and pressure half-time both returned to values similar to baseline values after immunosuppressive therapy (p less than 0.05 and p less than 0.0005, respectively). With 20% decrease in pressure half-time as a criterion for acute rejection, sensitivity was 88%, specificity 87% and positive predictive value 85%. Thus, Doppler echocardiographic evaluation of left ventricular diastolic function provides an excellent tool for early detection of acute rejection and noninvasive monitoring of the cardiac transplant recipient.
No takes yet. Share an insight, caveat, or question.
Desruennes et al. (1988) conducted an observational in Acute cardiac allograft rejection (n=55). Serial Doppler echocardiography (20% decrease in pressure half-time criterion) vs. Endomyocardial biopsy (patients without histopathologic rejection) was evaluated on Decrease in pressure half-time and isovolumic relaxation time for detecting acute rejection (Sensitivity 88%, Specificity 87%, PPV 85%, p=<0.0005). Serial Doppler echocardiography using a 20% decrease in pressure half-time detected acute cardiac rejection with 88% sensitivity, 87% specificity, and 85% PPV.
Synapse has enriched 10 related papers. Consider them for comparative context: